Abstract
Single-storey precast reinforced concrete (RC) frame type buildings are mainly preferred in manufacturing plants and storehouses. The behaviour of semi-rigid beam-column connections of the buildings is one of the main sources of uncertainty. The common damages observed after credible earthquakes were falling off large-span beams and large plastic deformations at the column base. New generation Lead Extrusion Damper (LED) developed by the authors is utilized in the seismic retrofitting of these buildings in use. This paper discusses the seismic performances of pre- and post-behaviour of the retrofitted buildings and evaluates the efficiency of the applied retrofitting technique. It is exposed that seismic demands are diminished essentially. The relative storey drifts decrease by about 40-90% while the reduction in the strain at the column base section reaches to 70%.
| Original language | English |
|---|---|
| Article number | 106167 |
| Journal | Soil Dynamics and Earthquake Engineering |
| Volume | 135 |
| DOIs | |
| Publication status | Published - Aug 2020 |
Bibliographical note
Publisher Copyright:© 2020 Elsevier Ltd
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 9 Industry, Innovation, and Infrastructure
Keywords
- Column type structure
- Lead extrusion damper
- Manufacturing plants
- Pinned beam-to-column connections
- Precast structures
- Retrofitting
- Seismic performance
Fingerprint
Dive into the research topics of 'Seismic performance improvement of single-storey precast reinforced concrete industrial buildings in use'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver