Abstract
Sector determination for a normalised space vector pulse width modulation (SVPWM) scheme is proposed for four-switch three-phase (FSTP) voltage source inverter (VSI) by using already available stationary reference frame stator voltages without requiring complex trigonometric calculations. The proposed method has been simulated by using MATLAB/Simulink and implemented using a VSI with a TMS320F28335 floating-point digital signal processing. Simulation and experimental results show the feasibility and effectiveness of the proposed SVPWM algorithm for FSTP inverter.
Original language | English |
---|---|
Pages (from-to) | 343-345 |
Number of pages | 3 |
Journal | Electronics Letters |
Volume | 53 |
Issue number | 5 |
DOIs | |
Publication status | Published - Mar 2017 |
Externally published | Yes |
Bibliographical note
Publisher Copyright:© The Institution of Engineering and Technology 2017.