Parametric reconstruction of kinetic PET data with plasma function estimation

Mustafa E. Kamasak*, Charles A. Bouman, Evan D. Morris, Ken Sauer

*Corresponding author for this work

Research output: Contribution to journalConference articlepeer-review

6 Citations (Scopus)

Abstract

It is often necessary to analyze the time response of a tracer. A common way of analyzing the tracer time response is to use a compartment model and estimate the model parameters. The model parameters are generally physiologically meaningful and called "kinetic parameters". In this paper, we simultaneously estimate both the kinetic parameters at each voxel and the model-based plasma input function directly from the sinogram data. Although the plasma model parameters are not our primary interest, they are required for accurate reconstruction of kinetic parameters. The plasma model parameters are initialized with an image domain method to avoid local minima, and multiresolution optimization is used to perform the required reconstruction. Good initial guesses for the plasma parameters are required for the algorithm to converge to the correct answer. Therefore, we devised a preprocessing step involving clustering of the emission images by temporal characteristics to find a reasonable plasma curve that was consistent with the kinetics of the multiple tissue types. We compare the root mean squared error (RMSE) of the kinetic parameter estimates with the measured (true) plasma input function and with the estimated plasma input function. Tests using a realistic rat head phantom and a real plasma input function show that we can simultaneously estimate the kinetic parameters of the two-tissue compartment model and plasma input function. The RMSE of the kinetic parameters increased for some parameters and remained the same or decreased for other parameters.

Original languageEnglish
Article number30
Pages (from-to)293-304
Number of pages12
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume5674
DOIs
Publication statusPublished - 2005
Externally publishedYes
EventProceedings of SPIE-IS and T Electronic Imaging - Computational Imaging III - San Jose, CA, United States
Duration: 17 Jan 200518 Jan 2005

Keywords

  • Dynamic PET
  • Input function estimation
  • Iterative reconstruction
  • Kinetic modeling
  • Tomography

Fingerprint

Dive into the research topics of 'Parametric reconstruction of kinetic PET data with plasma function estimation'. Together they form a unique fingerprint.

Cite this