N-Isopropylacrylamide/monoalkyl itaconate copolymers and N-isopropylacrylamide/itaconic acid/dimethyl itaconate terpolymers

Candan Erbil*, Yalçin Yildiz, Nurseli Uyanik

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

11 Citations (Scopus)

Abstract

Temperature- and pH-sensitive copolymers and terpolymers of N-isopropylacrylamide (NIPAAm) with itaconic acid (IA), monomethyl itaconate (MMeI), monobutyl itaconate (MBuI), monooctyl itaconate (MOcI), monocetyl itaconate (MCeI), and dimethyl itaconate (DMI) were prepared by free radical solution polymerization method. The dependence of coil-to-globule transition on pH and composition, molecular structures, and reactivities of monoalkyl itaconates, molecular weight distributions, and glass transition temperatures of copolymers and terpolymers were investigated using FT-IR and UV-visible spectroscopic techniques, gel permeation chromatography (GPC), differential scanning calorimetry (DSC), and acid-base titration methods. The temperature-/pH-dependent coil-to-globule transition measurements showed that, upon increasing the content and length of alkyl chains, the lower critical solution temperatures (LCSTs) were shifted to higher temperatures. This meant that with increase in the length of hydrophobic alkyl chain in the monoitaconates intramolecular intreactions between the carboxyl groups were suppressed and LCSTs increased. The aqueous solution behaviors of NIPAAm/IA/DMI terpolymers also revealed that, even if the terpolymer hydrophobicity is increased by adding DMI units, the presence of IA units overcame the decrease in hydrophilicity of the terpolymers. The presence of DMI units in the terpolymers balanced the hydrophilic character of IA. DSC results supported the ones obtained from the pH-dependent coil-to-globule transition measurements. An increase in both the chain length of alkyl groups attached to the monoitaconates and the contents of the mono- and dialkyl itaconates in the copolymers and terpolymers decreased the Tgs. In the case of NIPAAm/IA and NIPAAm/MMeI copolymers, the presence of the carboxyl groups forming hydrogen bonds increased the Tg, while the monoalkyl and dialkyl itaconates such as MBuI, MOcI, MCeI and DMI lead to a decrease in Tg of copolymSers and terpolymers because of the suppression of intramolecular interactions (resulting from the -COOH and -COO groups) through the longer alkyl spacers. The dependence of the thermosensitivity of these NIPAAm copolymers and terpolymers on different conditions of pH, and the nature and content of comonomers suggests that they can be useful in biotechnology and drug delivery applications which involve small changes in pH and temperature.

Original languageEnglish
Pages (from-to)926-933
Number of pages8
JournalPolymers for Advanced Technologies
Volume20
Issue number12
DOIs
Publication statusPublished - 2009

Keywords

  • Acid-base titrations
  • Cloud point measurements
  • Glass transition temperatures
  • N-isopropylacrylamide/itaconic acid/dimethyl itaconate terpolymers
  • N-isopropylacrylamide/monoalkyl itaconate copolymers
  • Poly(N-isopropylacrylamide)

Fingerprint

Dive into the research topics of 'N-Isopropylacrylamide/monoalkyl itaconate copolymers and N-isopropylacrylamide/itaconic acid/dimethyl itaconate terpolymers'. Together they form a unique fingerprint.

Cite this