Matrix interference free determination of perchlorate in urine by ion association-ion chromatography-mass spectrometry

P. Kalyani Martinelango, Gülçin Gümüş, Purnendu K. Dasgupta*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

35 Citations (Scopus)

Abstract

Quantitative measurement of perchlorate in biological fluids is of importance to assess its toxicity and to study its effects on the thyroid gland. Whenever possible, urine samples are preferred in toxicologic/epidemiologic studies because sample collection is non-invasive. We present here a pretreatment method for the determination of perchlorate in urine samples that lead to a clean matrix. Urine samples, spiked with isotopically labeled perchlorate, are exposed to UV to destroy/decompose organic molecules and then sequentially treated with an H+-form cation exchange resin to remove protolyzable compounds, with ammonia to raise the pH to 10-11 and finally passed through a mini-column of basic alumina to remove the color and other organic matter. After filtration through a 0.45 μm syringe filter, the sample thus prepared can be directly injected into an ion chromatograph (IC). We use ion association-electrospray ionization-mass spectrometry (ESI-MS) to detect and quantify perchlorate. The proposed sample preparation method leads to excellent limits of detection (LOD's) for perchlorate since there is essentially no dilution of sample and the matrix effects are eliminated. Results of urine samples from both men and women volunteers are reported for perchlorate, as well as for iodide and thiocyanate, which are generally present at much higher concentrations and for which a "dilute and shoot" approach is adequate. The limit of detection (S/N = 3) for iodide, thiocyanate and perchlorate by the present method was 0.40, 0.10 and 0.080 μg l-1, respectively.

Original languageEnglish
Pages (from-to)79-86
Number of pages8
JournalAnalytica Chimica Acta
Volume567
Issue number1 SPEC. ISS.
DOIs
Publication statusPublished - 10 May 2006
Externally publishedYes

Funding

This research was supported partly by the Dionex Corporation and partly by the Paul Whitfield Horn Professorship funds at Texas Tech University. GG thanks Istanbul Technical University for supporting her stay at TTU.

FundersFunder number
Dionex Corporation
Texas Tech University

    Keywords

    • Ion chromatography
    • Mass spectrometry
    • Perchlorate
    • Sample preparation
    • Urine

    Fingerprint

    Dive into the research topics of 'Matrix interference free determination of perchlorate in urine by ion association-ion chromatography-mass spectrometry'. Together they form a unique fingerprint.

    Cite this