Limitations on dominant pole pair selection with continuous PI and PID controllers

Research output: Contribution to conferencePaperpeer-review

18 Citations (Scopus)

Abstract

In the dominant pole placement approach, it is important non-dominant poles to be located far away from the dominant pole pair. Otherwise, predicting the closed-loop system transient response is difficult and satisfying the performance criteria becomes very challenging. It is known that PI and PID controllers are well-known and commonly used controllers in industrial applications. However, it is not possible to assign all of the closed-loop poles for higher order systems using such controllers because of the small number of controller parameters to be tuned. Therefore, the remaining poles may be located in the dominant region for a chosen dominant pole pair. In this study, it is aimed to find the limitations on dominant pole pair selection such that the unassigned poles can be located "m" times away from the design poles with PI and PID controllers. The success of the method is demonstrated on numerical examples.

Original languageEnglish
Pages741-745
Number of pages5
DOIs
Publication statusPublished - 18 Oct 2016
Event3rd International Conference on Control, Decision and Information Technologies, CoDIT 2016 - Saint Julian's, Malta
Duration: 6 Apr 20168 Apr 2016

Conference

Conference3rd International Conference on Control, Decision and Information Technologies, CoDIT 2016
Country/TerritoryMalta
CitySaint Julian's
Period6/04/168/04/16

Bibliographical note

Publisher Copyright:
© 2016 IEEE.

Keywords

  • Dominant Pole Region
  • PID Controllers
  • Pole Placement
  • Routh-Hurwitz Criterion
  • SISO LTI Systems

Fingerprint

Dive into the research topics of 'Limitations on dominant pole pair selection with continuous PI and PID controllers'. Together they form a unique fingerprint.