TY - GEN
T1 - Laboratory performance of x-ray detector on 2u cubesat beeaglesat
AU - Kalemci, Emrah
AU - Asian, Alim Rustem
AU - Bas, Mustafa Erdem
AU - Aksulu, Mehmet Deniz
AU - Akyol, Isa Eray
AU - Uludag, Mehmet Sevket
PY - 2015
Y1 - 2015
N2 - A CdZnTe based semiconductor X-ray detector (XRD) and its associated readout electronics has been developed by the Space Systems Design and Testing Laboratory of Istanbul Technical University and the High Energy Astrophysics Detector I-Aboratory of Sabanci University along with an SME partner. The XRD will be the secondary science mission on board BeEagleSat, which is developed as one of the double CubeSats for the QB50 project. QB50 is a European Framework 7 projcct carried out by a number of international organizations led by the von Karman Institute of Belgium. The heart of the XRD is a 2.5 mm thick, 15 mm x 15 mm CdZnTe crystal with orthogonal electrode strips on top and bottom for position resolution on the crystal. There are 3 sets of steering electrodes in between anodes. A commercial off the shelf (COTS) high voltage source provides necessary potential difference to transport electrons and holes towards electrodes. The signals from each strip are read by a COTS ASIC, RENA-3b, controlled my MSP 430. The XRD board (single -10 cm x 10 cm board) also carries the necessary power regulators and 7 COTS batteries. In a previous paper presented at the IAC 2014, we discussed the main design of the XRD and provided results from some of the early vibration tests of the mechanical design. At the time, the CdZnTe crystal has not been attached, and the readout electronics and software were still in development phase. In this paper, we present the laboratory performance of the electronic readout system and discuss the current phase of the XRD development.
AB - A CdZnTe based semiconductor X-ray detector (XRD) and its associated readout electronics has been developed by the Space Systems Design and Testing Laboratory of Istanbul Technical University and the High Energy Astrophysics Detector I-Aboratory of Sabanci University along with an SME partner. The XRD will be the secondary science mission on board BeEagleSat, which is developed as one of the double CubeSats for the QB50 project. QB50 is a European Framework 7 projcct carried out by a number of international organizations led by the von Karman Institute of Belgium. The heart of the XRD is a 2.5 mm thick, 15 mm x 15 mm CdZnTe crystal with orthogonal electrode strips on top and bottom for position resolution on the crystal. There are 3 sets of steering electrodes in between anodes. A commercial off the shelf (COTS) high voltage source provides necessary potential difference to transport electrons and holes towards electrodes. The signals from each strip are read by a COTS ASIC, RENA-3b, controlled my MSP 430. The XRD board (single -10 cm x 10 cm board) also carries the necessary power regulators and 7 COTS batteries. In a previous paper presented at the IAC 2014, we discussed the main design of the XRD and provided results from some of the early vibration tests of the mechanical design. At the time, the CdZnTe crystal has not been attached, and the readout electronics and software were still in development phase. In this paper, we present the laboratory performance of the electronic readout system and discuss the current phase of the XRD development.
UR - http://www.scopus.com/inward/record.url?scp=84991466895&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84991466895
T3 - Proceedings of the International Astronautical Congress, IAC
SP - 4330
EP - 4337
BT - 66th International Astronautical Congress 2015, IAC 2015
PB - International Astronautical Federation, IAF
T2 - 66th International Astronautical Congress 2015: Space - The Gateway for Mankind's Future, IAC 2015
Y2 - 12 October 2015 through 16 October 2015
ER -