TY - JOUR
T1 - High-performance carbon black electrode for oxygen reduction reaction and oxidation of atrazine by electro-Fenton process
AU - Karatas, Okan
AU - Gengec, Nevin Atalay
AU - Gengec, Erhan
AU - Khataee, Alireza
AU - Kobya, Mehmet
N1 - Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2022/1
Y1 - 2022/1
N2 - The aim of this study is to produce an electrode that can be used in H2O2 production and Electro-Fenton (EF) process by an effective, cheap, and easy method. For this reason, a superhydrophobic electrode with a higher PTFE ratio and high thickness was produced with a simple press. The produced electrode was used in the production of H2O2 and mineralization of Atrazine. First, the effect of pH, cathode voltage, and operation time on H2O2 production was evaluated. The maximum H2O2 concentration (409 mg/L), the highest current efficiency (99.80%), and the lowest electrical energy consumption (3.16 kWh/kg) were obtained at 0.8 V, 7.0 of pH, and 120 min, and the stability of the electrode was evaluated up to 720 min. Then, the effects of the operational conditions (pH, cathode voltage, operating time, and catalyst concentration) in electro-Fenton were evaluated. The fastest degradation of Atrazine (>99%) was obtained at 2.0 V, 3.0 of pH, and 0.3 mM of Fe2+ in 15 min. In the final part of the study, the degradation intermediates were identified, and the characterization of the electrode was evaluated by SEM, XRD, FT-IR, tensiometer, potentiostat, and elemental analyzer.
AB - The aim of this study is to produce an electrode that can be used in H2O2 production and Electro-Fenton (EF) process by an effective, cheap, and easy method. For this reason, a superhydrophobic electrode with a higher PTFE ratio and high thickness was produced with a simple press. The produced electrode was used in the production of H2O2 and mineralization of Atrazine. First, the effect of pH, cathode voltage, and operation time on H2O2 production was evaluated. The maximum H2O2 concentration (409 mg/L), the highest current efficiency (99.80%), and the lowest electrical energy consumption (3.16 kWh/kg) were obtained at 0.8 V, 7.0 of pH, and 120 min, and the stability of the electrode was evaluated up to 720 min. Then, the effects of the operational conditions (pH, cathode voltage, operating time, and catalyst concentration) in electro-Fenton were evaluated. The fastest degradation of Atrazine (>99%) was obtained at 2.0 V, 3.0 of pH, and 0.3 mM of Fe2+ in 15 min. In the final part of the study, the degradation intermediates were identified, and the characterization of the electrode was evaluated by SEM, XRD, FT-IR, tensiometer, potentiostat, and elemental analyzer.
KW - Atrazine
KW - Carbon black
KW - Electro-fenton
KW - Electro-oxidation
KW - Hydrogen peroxide
UR - http://www.scopus.com/inward/record.url?scp=85115977896&partnerID=8YFLogxK
U2 - 10.1016/j.chemosphere.2021.132370
DO - 10.1016/j.chemosphere.2021.132370
M3 - Article
C2 - 34592209
AN - SCOPUS:85115977896
SN - 0045-6535
VL - 287
JO - Chemosphere
JF - Chemosphere
M1 - 132370
ER -