Abstract
Abstract-Pollutants of primary interest are SO CO, NO, methane and other volatile organics, and paniculate matter. First- and second-law efficiencies have been evaluated. Next, the turbulent flows of exhaust gases through the stack have been modeled for both natural draft stacks and stacks equipped with forced draft fans. Velocity and temperature profiles in the stacks and for the plumes have been obtained from the numerical model for specified meteorological conditions.
Original language | English |
---|---|
Pages (from-to) | 681-692 |
Number of pages | 12 |
Journal | Energy |
Volume | 22 |
Issue number | 7 |
DOIs | |
Publication status | Published - 1997 |