Flow tones in a pipeline-cavity system: Effect of pipe asymmetry

D. Erdem, D. Rockwell*, P. Oshkai, M. Pollack

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

9 Citations (Scopus)

Abstract

Flow tones in a pipeline-cavity system are characterized in terms of unsteady pressure within the cavity and along the pipe. The reference case corresponds to equal lengths of pipe connected to the inlet and outlet ends of the cavity. Varying degrees of asymmetry of this pipe arrangement are investigated. The asymmetry is achieved by an extension of variable length, which is added to the pipe at the cavity outlet. An extension length as small as a few percent of the acoustic wavelength of the resonant mode can yield a substantial reduction in the pressure amplitude of the flow tone. This amplitude decrease occurs in a similar fashion within both the cavity and the pipe resonator, which indicates that it is a global phenomenon. Furthermore, the decrease of pressure amplitude is closely correlated with a decrease of the Q (quality)-factor of the predominant spectral component of pressure. At a sufficiently large value of extension length, however, the overall form of the pressure spectrum recovers to the form that exists at zero length of the extension. Further insight is provided by variation of the inflow velocity at selected values of extension length. Irrespective of its value, both the magnitude and frequency of the peak pressure exhibit a sequence of resonant-like states. Moreover, the maximum attainable magnitude of the peak pressure decreases with increasing extension length.

Original languageEnglish
Pages (from-to)511-523
Number of pages13
JournalJournal of Fluids and Structures
Volume17
Issue number4
DOIs
Publication statusPublished - Mar 2003
Externally publishedYes

Funding

The authors are grateful for financial support under Office of Naval Research Grant No. N00014-98-1-0817.

FundersFunder number
Office of Naval Research

    Fingerprint

    Dive into the research topics of 'Flow tones in a pipeline-cavity system: Effect of pipe asymmetry'. Together they form a unique fingerprint.

    Cite this