Abstract
Localized cryogenic exposure can generate severe structural demand in LNG containment even when initial yielding is not predicted, because the response depends on thermal incompatibility and restraint rather than minimum temperature alone. This study presents a failure-oriented finite element assessment of a large 9% Ni steel LNG tank subjected to localized liquid nitrogen (LN2) surrogate exposure. A sequential thermal–structural framework with a boiling-controlled film boundary was evaluated against published EH36 plate-cooling measurements, yielding an RMSE of 9.33 °C and R2=0.983. The tank response was interpreted through thermal-strain incompatibility, temperature-dependent strength utilization, local stress-state evolution, spatial stress redistribution, and restraint-induced hot-spot migration. The maximum local thermal-strain mismatch developed during the early cooling stage, whereas the governing global von Mises stress of 469.1 MPa occurred later at 590.5 s. Despite substantial decay of the local mismatch, the critical stress remained near its maximum, indicating increasing control by broader structural compatibility and restraint. The baseline case remained elastic, with a yield-utilization ratio of 0.567 and zero accumulated equivalent plastic strain. Foundation compliance shifted the governing hot spot from the lower-wall transition to the outer bottom plate, while an instantaneous prescribed − 196 °C reference produced a 14.4% higher peak stress. The results demonstrate that cryogenic failure screening should consider cooling-path evolution, differential thermal contraction, and structural restraint together when identifying failure-critical regions in LNG containment systems.
| Original language | English |
|---|---|
| Journal | Journal of Failure Analysis and Prevention |
| DOIs | |
| Publication status | Accepted/In press - 2026 |
Bibliographical note
Publisher Copyright:© ASM International 2026.
Keywords
- 9% Ni steel
- Cryogenic thermal shock
- Failure screening
- Finite element analysis
- LNG storage tank
- Structural integrity
- Thermal-stress localization
- Transient heat transfer
Fingerprint
Dive into the research topics of 'Failure-Oriented Assessment of Cryogenic Thermal-Stress Localization in a 9% Ni Steel LNG Tank'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver