Experimental investigation of heat transfer coefficients between hydronic radiant heated wall and room

Aliihsan Koca*, Zafer Gemici, Yalcin Topacoglu, Gursel Cetin, Rusen Can Acet, Baris Burak Kanbur

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

77 Citations (Scopus)

Abstract

The reason radiant heating systems are highly preferred in recently designed or a modernized construction is due to their energy efficiency and low exergy destruction. Radiant heating systems are different from typical HVAC systems because they heat surfaces rather than air and can save large amounts of energy while providing higher levels of comfort. The fundamental design parameters for a radiant heating system are heat transfer coefficients such as radiation, convection and total heat transfer coefficients. In this study, the values of radiant, convective and total heat transfer coefficients were calculated based on the experimental results that were taken from the climatic test chamber. This article presents the results based on an experimental research on heated radiant hydronic wall panels mounted in the climatic test chamber. The aim was to estimate the values of heat transfer coefficients for different location configurations of radiant wall heating panels experimentally. This experimental study was conducted under the location configurations of 3 different wall panel arrangements for 7 water flow temperatures ranging from 30 °C to 42 °C. It was noticed that the amount of radiation heat transfer increased when the crosswise area of the window surface was heated and simultaneously the heat transfer capability of radiation rose by 70% of the total heat transfer.

Original languageEnglish
Pages (from-to)211-221
Number of pages11
JournalEnergy and Buildings
Volume82
DOIs
Publication statusPublished - Oct 2014
Externally publishedYes

Funding

This study was supported by the project number TEYDEB 3100577 and financed by The Scientific and Technological Research Council of Turkey (Tubitak) . This work has been a part of the project of Mir Arastirma and Gelistirme AS company department of thermo-fluid and energy research.

FundersFunder number
Türkiye Bilimsel ve Teknolojik Araştirma Kurumu

    Keywords

    • Convection
    • Heat transfer coefficient
    • Radiant wall heating system
    • Radiation
    • Thermal comfort

    Fingerprint

    Dive into the research topics of 'Experimental investigation of heat transfer coefficients between hydronic radiant heated wall and room'. Together they form a unique fingerprint.

    Cite this