Abstract

In the study, exergy analysis of steady laminar fluid flow in stainless steel microtubes with diameters between 103 μm and 179 μm were conducted in the adiabatic conditions experimentally. The exergy losses were obtained for deionised water flowing in rough microtubes with the surface relative roughness of 2-6%. Results indicated that the exergy loss was in a good agreement with the conventional theory and the increasing in relative roughness leads to increasing exergy loss. As Re increases, measured exergy losses were found to be significantly higher than that of the predicted values

Original languageEnglish
Pages (from-to)472-485
Number of pages14
JournalInternational Journal of Exergy
Volume9
Issue number4
DOIs
Publication statusPublished - Dec 2011
Externally publishedYes

Keywords

  • Exergy
  • Microtube
  • Second law analysis

Fingerprint

Dive into the research topics of 'Exergy analysis of laminar fluid flow in stainless steel microtubes'. Together they form a unique fingerprint.

Cite this