Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions

Altin Maraj*, Andonaq Londo, Alemayehu Gebremedhin, Coskun Firat

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

60 Citations (Scopus)

Abstract

This work represents the energy performance analysis during the annual time period of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector having an aperture area of 1.476 m2 under the Mediterranean climate conditions. For the purpose, recorded data from a field-trial installation are exploited. The recorded data obtained every minute are used to perform the energy analysis during an annual period. The analysis is performed by using mathematical models and by representing the results for each month. Monthly values of measured parameters and calculated quantities offered a clear view regarding the operation of the considered field-trial installation for this climate region. For an annual irradiation on solar collector plane of 2,212 kWh/year, it was noticed that the annual useful heat gain for the heat pipe evacuated solar tube collector, the useful energy delivered by the solar circuit to the storage tank, and the delivered energy to the thermal consumer were 1,345 kWh/year, 1,311 kWh/year, and 1,009 kWh/year, respectively. The annual efficiency for the heat pipe evacuated solar tube collector was 0.62, while for the forced circulated system was 0.516. Also, the annual energy balance of the system obtained from the calculation is built.

Original languageEnglish
Pages (from-to)874-883
Number of pages10
JournalRenewable Energy
Volume140
DOIs
Publication statusPublished - Sept 2019

Bibliographical note

Publisher Copyright:
© 2019

Funding

The authors acknowledge the financial support from the Agency for Research, Technology, and Innovation- Government of Albania through the project “Water and Energy 2010–2012”, No. 397. The utilized trial solar water heating system was provided through this project, which included also a dissertation thesis.

FundersFunder number
Agency for Research, Technology, and Innovation- Government of Albania397

    Keywords

    • Collector efficiency
    • Forced circulation
    • Heat pipe
    • Solar fraction
    • System efficiency
    • Useful energy gain

    Fingerprint

    Dive into the research topics of 'Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions'. Together they form a unique fingerprint.

    Cite this