TY - JOUR
T1 - Effects of 1800 MHz and 2100 MHz mobile phone radiation on the blood–brain barrier of New Zealand rabbits
AU - Kizilçay, Abdullah Oğuz
AU - Tütüncü, Bilal
AU - Koçarslan, Mehmet
AU - Gözel, Mahmut Ahmet
N1 - Publisher Copyright:
© International Federation for Medical and Biological Engineering 2024.
PY - 2024
Y1 - 2024
N2 - In this study, the impact of mobile phone radiation on blood–brain barrier (BBB) permeability was investigated. A total of 21 New Zealand rabbits were used for the experiments, divided into three groups, each consisting of 7 rabbits. One group served as the control, while the other two were exposed to electromagnetic radiation at frequencies of 1800 MHz with a distance of 14.5 cm and 2100 MHz with a distance of 17 cm, maintaining a constant power intensity of 15 dBm, for a duration equivalent to the current average daily conversation time of 38 min. The exposure was conducted under non-thermal conditions, with RF radiation levels approximately ten times lower than normal values. Evans blue (EB) dye was used as a marker to assess BBB permeability. EB binds to plasma proteins, and its presence in brain tissue indicates a disruption in BBB integrity, allowing for a quantitative evaluation of radiation-induced permeability changes. Left and right brain tissue samples were analyzed using trichloroacetic acid (TCA) and phosphate-buffered solution (PBS) solutions to measure EB amounts at 620 nm via spectrophotometry. After the experiments, BBB tissue samples were collected from the right and left brains of all rabbits in the three groups and subjected to a series of medical procedures. Samples from Group 1 were compared with those from Group 2 and Group 3 using statistical methods to determine if there were any significant differences. As a result, it was found that there was no statistically significant difference in the BBB of rabbits exposed to 1800 MHz radiation, whereas there was a statistically significant difference at a 95% confidence level in the BBB of rabbits exposed to 2100 MHz radiation. A decrease in EB values was observed upon the arithmetic examination of the BBB. Graphical Abstract: (Figure presented.)
AB - In this study, the impact of mobile phone radiation on blood–brain barrier (BBB) permeability was investigated. A total of 21 New Zealand rabbits were used for the experiments, divided into three groups, each consisting of 7 rabbits. One group served as the control, while the other two were exposed to electromagnetic radiation at frequencies of 1800 MHz with a distance of 14.5 cm and 2100 MHz with a distance of 17 cm, maintaining a constant power intensity of 15 dBm, for a duration equivalent to the current average daily conversation time of 38 min. The exposure was conducted under non-thermal conditions, with RF radiation levels approximately ten times lower than normal values. Evans blue (EB) dye was used as a marker to assess BBB permeability. EB binds to plasma proteins, and its presence in brain tissue indicates a disruption in BBB integrity, allowing for a quantitative evaluation of radiation-induced permeability changes. Left and right brain tissue samples were analyzed using trichloroacetic acid (TCA) and phosphate-buffered solution (PBS) solutions to measure EB amounts at 620 nm via spectrophotometry. After the experiments, BBB tissue samples were collected from the right and left brains of all rabbits in the three groups and subjected to a series of medical procedures. Samples from Group 1 were compared with those from Group 2 and Group 3 using statistical methods to determine if there were any significant differences. As a result, it was found that there was no statistically significant difference in the BBB of rabbits exposed to 1800 MHz radiation, whereas there was a statistically significant difference at a 95% confidence level in the BBB of rabbits exposed to 2100 MHz radiation. A decrease in EB values was observed upon the arithmetic examination of the BBB. Graphical Abstract: (Figure presented.)
KW - Blood–brain barrier
KW - Electromagnetic radiation
KW - GSM frequencies
KW - New Zealand rabbit
UR - http://www.scopus.com/inward/record.url?scp=85209092777&partnerID=8YFLogxK
U2 - 10.1007/s11517-024-03238-1
DO - 10.1007/s11517-024-03238-1
M3 - Article
AN - SCOPUS:85209092777
SN - 0140-0118
JO - Medical and Biological Engineering and Computing
JF - Medical and Biological Engineering and Computing
ER -