T1 - Detection and estimation of embolic Doppler signals using discrete wavelet transform
AU - Aydin, N.
AU - Markus, H. S.
AU - Marvasti, F.
PY - 2001
Y1 - 2001
N2 - Almost any system for the detection of asymptomatic circulating emboli by Doppler ultrasound employs the fast Fourier Transform (FFT). However, the FFT is not ideally suited to study short-lived embolic signals. The wavelet transform (WT) is an optimized way of analyzing short-lived signals and performs better than the FFT in some respect. We propose a detection method based on the discrete wavelet transform (DWT) and study some parameters, which might be useful for describing embolic signals. We used 2 independent data sets, comprising 100 low intensity embolic signals, 100 various type of artifacts and 100 Doppler speckle. After applying the DWT to the data, several parameters were evaluated. The threshold values used for both data sets were optimized using the first data set. 98 out of 100 embolic signals were detected as embolic signals for the first data set. 95 out of 100 embolic signals were detected for the second data set when the same threshold values were used.
AB - Almost any system for the detection of asymptomatic circulating emboli by Doppler ultrasound employs the fast Fourier Transform (FFT). However, the FFT is not ideally suited to study short-lived embolic signals. The wavelet transform (WT) is an optimized way of analyzing short-lived signals and performs better than the FFT in some respect. We propose a detection method based on the discrete wavelet transform (DWT) and study some parameters, which might be useful for describing embolic signals. We used 2 independent data sets, comprising 100 low intensity embolic signals, 100 various type of artifacts and 100 Doppler speckle. After applying the DWT to the data, several parameters were evaluated. The threshold values used for both data sets were optimized using the first data set. 98 out of 100 embolic signals were detected as embolic signals for the first data set. 95 out of 100 embolic signals were detected for the second data set when the same threshold values were used.
UR - http://www.scopus.com/inward/record.url?scp=0034853032&partnerID=8YFLogxK
U2 - 10.1109/ICASSP.2001.941099
DO - 10.1109/ICASSP.2001.941099
M3 - Article
AN - SCOPUS:0034853032
SN - 1520-6149
VL - 2
SP - 1049
EP - 1052
JO - Proceedings - ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing
JF - Proceedings - ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing
ER -