CuO nanosheets-enhanced flow-injection chemiluminescence system for determination of vancomycin in water, pharmaceutical and human serum

A. R. Khataee*, A. Hasanzadeh, M. Iranifam, M. Fathinia, Y. Hanifehpour, S. W. Joo

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

34 Citations (Scopus)

Abstract

A novel, rapid and sensitive CuO nanosheets (NSs) amplified flow-injection chemiluminescence (CL) system, luminol-H2O2-CuO nanosheets, was developed for determination of the vancomycin hydrochloride for the first time. It was found that vancomycin could efficiently inhibit the CL intensity of luminol-H2O2-CuO nanosheets system in alkaline medium. Under the optimum conditions, the inhibited CL intensity was linearly proportional to the concentration of vancomycin over the ranges of 0.5-18.0 and 18.0-40.0 mg L-1, with a detection limit (3σ) of 0.1 mg L-1. The precision was calculated by analyzing samples containing 5.0 mg L-1 vancomycin (n = 11) and the relative standard deviation (RSD) was 2.8%. Also, a high injection throughput of 120 sample h -1 was obtained. The CuO nanosheets were synthesized by a sonochemical method. Also, X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were employed to characterize the CuO nanosheets. The method was successfully employed to determine vancomycin hydrochloride in environmental water samples, pharmaceutical formulation and spiked human serum.

Original languageEnglish
Pages (from-to)737-743
Number of pages7
JournalSpectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
Volume122
DOIs
Publication statusPublished - 25 Mar 2014
Externally publishedYes

Keywords

  • CuO nanosheets
  • Flow-chemiluminescence
  • Luminol
  • Sonochemical
  • Vancomycin

Fingerprint

Dive into the research topics of 'CuO nanosheets-enhanced flow-injection chemiluminescence system for determination of vancomycin in water, pharmaceutical and human serum'. Together they form a unique fingerprint.

Cite this