Abstract
The turbulent mixed convection in a vertical flat duct under overpower wall transient is analysed numerically to simulate abnormal working conditions. A finite difference procedure based on LSOR is used to solve the governing equations. The effect of wall overpower transient on velocity, pressure and temperature fields and heat transfer on the walls are investigated for different periods which defines the severity of the abnormal situation. The abnormality is found to increase as the period decreases.
| Original language | English |
|---|---|
| Journal | International Symposium on Advances in Computational Heat Transfer |
| DOIs | |
| Publication status | Published - 1997 |
| Event | International Symposium on Advances in Computational Heat Transfer, CHT 1997 - Çeşme, Turkey Duration: 26 May 1997 → 30 May 1997 |
Bibliographical note
Publisher Copyright:© 1997, Begell House Inc. All rights reserved.
Fingerprint
Dive into the research topics of 'Computational study of turbulent mixed convection in vertical flat duct under overpower transient'. Together they form a unique fingerprint.Cite this