Comparative optical coherence tomography imaging of human esophagus: How accurate is localization of the muscularis mucosae?

Inci Çilesiz, Paul Fockens, Raphaela Kerindongo, Dirk Faber, Guido Tytgat, Fiebo Ten Kate, Ton Van Leeuwen*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

41 Citations (Scopus)

Abstract

Background: Early diagnosis of esophageal cancer limited to the mucosa allows local endoscopic treatment and thereby improves prognosis. Optical coherence tomography images of normal human esophageal tissue obtained with 2 systems with light sources that provide different wavelengths (800 nm and 1275 nm) were compared with histology to determine which wavelength is best suited for detailed optical coherence tomography imaging of the esophageal wall, and to precisely localize the muscularis mucosae. Methods: Within 1 hour of surgical resection, an esophageal specimen was cleaned of excess blood with saline solution and soaked in formalin for a minimum of 48 hours. After optical coherence tomography imaging, the specimen was prepared for routine histologic assessment. To precisely localize the different layers of the esophageal wall on an optical coherence tomography image, well-defined structures within the esophageal wall were sought. Results: The 1275 nm system with 12 μm resolution was superior in terms of imaging depth. As compared with histology, the 4 μm resolution of the 800 nm system made fine detail more visible. With minimal experience, the muscularis mucosae could be recognized with either system as a hyporeflective layer with a diameter of around 180 μm. Conclusions: Based on appearance and location of morphologic landmarks, layers of normal esophageal wall, specifically, the location and extent of the muscularis mucosae, could be recognized by using both the 800 nm and 1275 nm optical coherence tomography system. Although different conditions may be operative in vivo, the present ex vivo study further verifies by precise interpretation that optical coherence tomography provides precise images of the esophageal wall.

Original languageEnglish
Pages (from-to)852-857
Number of pages6
JournalGastrointestinal Endoscopy
Volume56
Issue number6
DOIs
Publication statusPublished - Dec 2002

Funding

Part of the research program of FOM [Stichting voor Fundamenteel Onderzoek der Materie, financially supported by NWO, the Nederlandse Organisatie voor Wetenschappelijk Onderzoek](IÇ, DF), and Philips Research (IÇ). This work was also funded by ZON [Zorg Onderzoek Nederland](RK).

FundersFunder number
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Philips Research Americas
Zorg Onderzoek Nederland
ZON
Stichting voor Fundamenteel Onderzoek der Materie
Nederlandse Organisatie voor Wetenschappelijk Onderzoek

    Fingerprint

    Dive into the research topics of 'Comparative optical coherence tomography imaging of human esophagus: How accurate is localization of the muscularis mucosae?'. Together they form a unique fingerprint.

    Cite this