Combination of a poly(3,4-ethylene-dioxythiophene) electrode in the presence of sodium dodecyl sulfate with centri-voltammetry

Yudum Tepeli, Sema Aslan, Esma Sezer*, Ulku Anik

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

9 Citations (Scopus)

Abstract

A poly(3,4-ethylene-dioxythiophene) (PEDOT) electrode was prepared by electropolymerization of 3,4-ethylene-dioxythiophene (EDOT) in the presence of sodium dodecyl sulfate (SDS). The electrode was combined with centri-voltammetry for the first time and applied for dopamine (DA) detection. Under the experimental conditions, SDS provides a high density of negative charges to the PEDOT electrode and by this way the electrode attracts the positively charged DA. Also by applying centrifugation, effective accumulation of DA onto the electrode surface was achieved. Two linear ranges 1 × 10-9 M to 1 × 10-5 M and 2 × 10-5 M to 1 × 10-1 M with two LOD values of 5.9 nM and 3.1 nM were found for the developed system. Sample application and interference study were also conducted.

Original languageEnglish
Pages (from-to)6740-6746
Number of pages7
JournalAnalytical Methods
Volume7
Issue number16
DOIs
Publication statusPublished - 21 Aug 2015

Bibliographical note

Publisher Copyright:
© 2015 The Royal Society of Chemistry.

Fingerprint

Dive into the research topics of 'Combination of a poly(3,4-ethylene-dioxythiophene) electrode in the presence of sodium dodecyl sulfate with centri-voltammetry'. Together they form a unique fingerprint.

Cite this