TY - JOUR
T1 - Biceps tenodesis with interference screw
T2 - Cyclic testing of different techniques
AU - Hapa, Onur
AU - Günay, Cüneyd
AU - Kömürcü, Erkam
AU - Çakıcı, Hüsamettin
AU - Bozdağ, Ergun
PY - 2010/12
Y1 - 2010/12
N2 - Different surgical techniques exist for biceps tenodesis. The most secure fixation technique is with interference screws. The purpose of the study was to compare the biomechanical performance of three different interference screw biceps tenodesis fixation methods, which involve different tunnel preparation methods. Using a sheep shoulder model and metal interference screws, a bone wedge technique was compared to serial tunnel dilation and a control group. After a preload, all repairs were cyclically loaded (20-60 N) for 100 cycles followed by destructive testing. Biceps tenodesis using an interference screw-bone wedge technique showed statistically lower cyclic displacement (8.1 ± 6.4 mm) than serial dilatation with an interference screw (21.3 ± 8.4 mm) or interference screw fixation alone (18.3 ± 8.3 mm) (P = 0.02). There were no statistically significant differences in ultimate failure strength for any of the interference screw biceps tenodesis techniques tested. The tunnel preparation method chosen for interference screw fixed biceps tenodesis can have a positive effect on tenodesis performance. Using the bone wedge technique may allow a more rapid rehabilitation program applicable for the traumatic biceps tendon rupture seen in young, athletic patients with high demands.
AB - Different surgical techniques exist for biceps tenodesis. The most secure fixation technique is with interference screws. The purpose of the study was to compare the biomechanical performance of three different interference screw biceps tenodesis fixation methods, which involve different tunnel preparation methods. Using a sheep shoulder model and metal interference screws, a bone wedge technique was compared to serial tunnel dilation and a control group. After a preload, all repairs were cyclically loaded (20-60 N) for 100 cycles followed by destructive testing. Biceps tenodesis using an interference screw-bone wedge technique showed statistically lower cyclic displacement (8.1 ± 6.4 mm) than serial dilatation with an interference screw (21.3 ± 8.4 mm) or interference screw fixation alone (18.3 ± 8.3 mm) (P = 0.02). There were no statistically significant differences in ultimate failure strength for any of the interference screw biceps tenodesis techniques tested. The tunnel preparation method chosen for interference screw fixed biceps tenodesis can have a positive effect on tenodesis performance. Using the bone wedge technique may allow a more rapid rehabilitation program applicable for the traumatic biceps tendon rupture seen in young, athletic patients with high demands.
KW - Biceps tenodesis
KW - Biomechanics
KW - Bone wedge technique
KW - Interference screw
KW - Serial tunnel dilation
KW - Shoulder
UR - http://www.scopus.com/inward/record.url?scp=78649946023&partnerID=8YFLogxK
U2 - 10.1007/s00167-010-1180-7
DO - 10.1007/s00167-010-1180-7
M3 - Article
AN - SCOPUS:78649946023
SN - 0942-2056
VL - 18
SP - 1779
EP - 1784
JO - Knee Surgery, Sports Traumatology, Arthroscopy
JF - Knee Surgery, Sports Traumatology, Arthroscopy
IS - 12
ER -