Abstract
The present study focuses on the entropy generation analysis in a circular duct with internal longitudinal fins of different shape for laminar flow. Three different fin shapes are chosen for the analysis: Thin, triangular and V-shaped fins. Calculations are performed for various dimensionless lengths and number of fins, dimensionless temperature difference and fin angle for triangular and V-shaped fins. It is found that the number of fins and dimensionless length of the fins for both thin fins and triangular fins, and the fin angle for triangular and V-shaped fins have significant effect on both entropy generation and pumping power. Further, both entropy generation and pumping power also are influenced by dimensionless temperature difference.
| Original language | English |
|---|---|
| Pages (from-to) | 171-181 |
| Number of pages | 11 |
| Journal | International Journal of Heat and Mass Transfer |
| Volume | 48 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - Jan 2005 |
| Externally published | Yes |
Keywords
- Circular duct
- Entropy generation
- Laminar flow
- Longitudinal fins