TY - GEN
T1 - Active flow control with an oscillating backward facing step
AU - Cadirci, Sertac
AU - Gunes, Hasan
PY - 2012
Y1 - 2012
N2 - An oscillatory, zero-net-mass flux actuator system, Jet and Vortex Actuator (JaVA), is implemented on the step wall of a backward facing step. JaVA is shown previously both experimentally and numerically that it can energize the boundary layer by creating jets or vortices thus it may delay flow separation when used properly. The main part of JaVA is a rectangular cavity with a moving actuator plate. The actuator plate is mounted asymmetrically inside the cavity of the JaVA box, such that there are one narrow and one wide gap between the plate and the box. The main governing parameters are the actuator plate's width (b), the amplitude (a) and the operating frequency (f). The main target of the control with active jets on the step wall is to influence directly the main recirculation zone, thus as the actuator plate or the step's vertical wall moves periodically in horizontal direction, a jet emerges into the recirculation zone. Non-dimensional numbers such as the scaled amplitude (Sa = 2πa/b) and the jet Reynolds number (ReJ = 4abf/v) as well as the maximum cross flow velocity characterize the JaVA-induced flow types and effects on the recirculation zone. One period consists of one blowing and one suction phase into the recirculation zone. The actuator plate has a sinusoidal motion determined by the amplitude and the operating frequency. Time-averaged flow fields and boundary layer profiles for actuated and not actuated cases at various operating frequencies indicate the effect of active flow control. The control effectiveness is given by the ratio of the jet Reynolds number to the Reynolds number of the incoming flow (r = ReJ/Re). A transient finite-volume-based laminar, incompressible Navier-Stokes solver (Fluent) has been used to study the flow fields generated by JaVA. The computational domain consists of a moving zone along the channel and the motion of the actuator plate is generated by a moving grid imposing appropriate boundary conditions with User-Defined-Functions (UDF). Numerical simulations reveal the JaVA-boundary layer interaction in the narrow channel for various governing parameters such as frequencies (jet Reynolds numbers) and channel flow velocities (Reynolds numbers, Re = 200, 400 and 800). The proposed control method based on suction and blowing with an oscillating backward facing step (OsBFS) seems to be effective in shortening the recirculation zone length and delaying the flow separation downstream of the backward facing step.
AB - An oscillatory, zero-net-mass flux actuator system, Jet and Vortex Actuator (JaVA), is implemented on the step wall of a backward facing step. JaVA is shown previously both experimentally and numerically that it can energize the boundary layer by creating jets or vortices thus it may delay flow separation when used properly. The main part of JaVA is a rectangular cavity with a moving actuator plate. The actuator plate is mounted asymmetrically inside the cavity of the JaVA box, such that there are one narrow and one wide gap between the plate and the box. The main governing parameters are the actuator plate's width (b), the amplitude (a) and the operating frequency (f). The main target of the control with active jets on the step wall is to influence directly the main recirculation zone, thus as the actuator plate or the step's vertical wall moves periodically in horizontal direction, a jet emerges into the recirculation zone. Non-dimensional numbers such as the scaled amplitude (Sa = 2πa/b) and the jet Reynolds number (ReJ = 4abf/v) as well as the maximum cross flow velocity characterize the JaVA-induced flow types and effects on the recirculation zone. One period consists of one blowing and one suction phase into the recirculation zone. The actuator plate has a sinusoidal motion determined by the amplitude and the operating frequency. Time-averaged flow fields and boundary layer profiles for actuated and not actuated cases at various operating frequencies indicate the effect of active flow control. The control effectiveness is given by the ratio of the jet Reynolds number to the Reynolds number of the incoming flow (r = ReJ/Re). A transient finite-volume-based laminar, incompressible Navier-Stokes solver (Fluent) has been used to study the flow fields generated by JaVA. The computational domain consists of a moving zone along the channel and the motion of the actuator plate is generated by a moving grid imposing appropriate boundary conditions with User-Defined-Functions (UDF). Numerical simulations reveal the JaVA-boundary layer interaction in the narrow channel for various governing parameters such as frequencies (jet Reynolds numbers) and channel flow velocities (Reynolds numbers, Re = 200, 400 and 800). The proposed control method based on suction and blowing with an oscillating backward facing step (OsBFS) seems to be effective in shortening the recirculation zone length and delaying the flow separation downstream of the backward facing step.
UR - http://www.scopus.com/inward/record.url?scp=84883854982&partnerID=8YFLogxK
U2 - 10.1115/ESDA2012-82645
DO - 10.1115/ESDA2012-82645
M3 - Conference contribution
AN - SCOPUS:84883854982
SN - 9780791844854
T3 - ASME 2012 11th Biennial Conference on Engineering Systems Design and Analysis, ESDA 2012
SP - 193
EP - 199
BT - ASME 2012 11th Biennial Conference on Engineering Systems Design and Analysis, ESDA 2012
T2 - ASME 2012 11th Biennial Conference on Engineering Systems Design and Analysis, ESDA 2012
Y2 - 2 July 2012 through 4 July 2012
ER -