Abstract
This paper presents a novel current control methodology for grid connected doubly-fed induction generator (DFIG) based wind energy conversion systems. Controller is based on a proportional controller with additional first order low pass filter disturbance observer which estimates the parameter dependent nonlinear feed-forward terms. The results in simulations and experimental test bed obviously demonstrate that decoupled control of active and reactive power is achieved without the necessity of additional machine parameter.
| Original language | English |
|---|---|
| Pages (from-to) | 186-195 |
| Number of pages | 10 |
| Journal | Automatika |
| Volume | 56 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - 27 Jul 2015 |
Bibliographical note
Publisher Copyright:© 2015, KoREMA. All rights reserved.
Keywords
- DFIG
- Disturbance observer
- Wind energy